971 reviews analysed
1. 30A Contactor 3 Pole, 110/120V Coil, Motor Load 32A, Lighting 40A, 50A, 600V IEC DIN
2. Electrodepot 30 Amp 3 Pole Contactor, 110-120V Coil, Motor Load 32A, Lighting 40A, 50A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 Millimeters x 6 Inches – 1 Piece with 2 Number 10 Screws
3. Eaton C25BNB230A Compact Definite Purpose Contactor, 30A Inductive Current Rating, 2 Max HP Rating at 115V, 5 Max HP Rating at 230V, 120VAC Coil Voltage
Feature
- Insulation Voltage: 690V
- Magnet Coil Class F, 155°C
- Operating temperature: -25 to +70°C
- Coil Power VAC: 2.2kW
- Coil Terminals: Screw with Quick Connect
- Coil Voltage AC Max: 120V
- Coil Voltage AC Min: 110V
- Contacts: DPST-NO-DB
- Horsepower: 3hp
- Line Voltage: 230V
- CE Compliant, CSA certified, UL Recognized
Description
Definite Purpose Contactor, Number of Poles 2, 30 Full Load Amps-Inductive, Coil Volts 120VAC, HP @ 1 Phase – 120V 2, HP @ 1 Phase – 230V 5, Height 3.19 In., Width 1.97 In., Depth 2.32 In., 40 Full Load Amps-Resistive, Hz 50/60, Action Nonreversing, Enclosure Type Open, Series F1, Includes Metal Mounting Plate, Binding Head Screw with Quick Connect Terminals, Standards UL, CSA, CE’
4. NTE Electronics R04-11A30-120 Series R4 General Purpose Multicontact AC Open Frame Relay, Heavy Duty, DPDT Contact Arrangement, 30 Amp, 120 VAC
Description
NTE’s extensive line of UL & CSA listed relays and accessories feature over 750 different NTE relays that you can cross reference to more than 85,000 industry types from 267 different suppliers. Included is a remarkable multifunctional programmable timer/counter that can be programmed to 10 different timing modes, two counting modes, and AC or DC input, slim-line I/O modules in industry standard packaging, PC mountable relays suitable for 5mm grid patterns, PC mountable relays for telecommunications, security and appliances, two different types of thermal circuit breakers, plus new industrial types for HVAC, machinery and equipment applications.
5. 12 Pole Contactor Normally Open Lighting Contactor 120V Coil, 4 x 3 Set 30A, 40A, 50A, 60A
6. Baomain AC Contactor CJX2-2510 110V Coil 50/60Hz 40A DIN Rail 3P Three Pole Normally Open(NO)
Description
7. 5Y6 40 Amp 4 Pole Normally Open NEMA 600V HVAC Definite Purpose Contactor – 110/120VAC Coil, Inductive 40A, Resistive 50A (Pack of 2)
Feature
- INDUSTRIAL QUALITY COMPONENTS – Pack of 2 40Amp 4 Pole Normally Open (NO) Definite Purpose Contactors for HVAC (Heating, Ventilating and Air Conditioning) installations in home and industry. Complies with NEMA 2 standard for consistent and reliable setting. Suitable for 8-pole connections
- APPLICATIONS – Heating, refrigeration and lighting. AC-1 for resistance furnaces, incandescent lamps or electric heaters
- and AC-3 for air conditioners, compressors or fans
- FULL AMP LOAD – Inductive/Motor Load: 40Amp. Resistive/Incandescent Load: 50Amp. DC Load: 30Amp @ 24VDC. Power Lug Terminal Capacity AWG # 4
- COIL VOLTAGE AND LOAD – Voltage: AC 110V/120V, 50/60Hz. Load: 67 VA Inrush and 15VA Sealed
- DIMENSIONS (approx.) – 77.00 x 95.80 x 77.00 mm / 3.00” x 3.77” x 3.00” (Width x Height x Depth)
Description
Pack of 2 40 Amp 4 Pole Normally Open NEMA 600V HVAC Definite Purpose Contactors for heating, refrigeration and lighting installations.
Complies with NEMA 2 standard.
Technical Specifications:
– AC 40A. Definite Purpose. 600V
– Max 2 HP Single Phase @ 115V, 10 HP @ 230V, 15 HP Three Phase @ 480V
– DC 30A 24VDC
– Coil:120VAC, 67VA inrush, 15VA sealed
– Normally Open (N.O.) main contacts
– UL Listed
– Coil 110/120 VAC
– Weight: 1.08 lb (0.55 kg)
– Dimensions: 77.00 x 95.80 x 77.00 mm (3.00” x 3.77” x 3.00′)
Compliance:
CSA C22.2 No. 14, EN 60947-4-1, EN 60947-5-1, IEC 947-2, IEC 60947-4-1, IEC 60947-5-1, UL 508, VDE 0660
8. Holdwell SA-2P-40A-120V 2 Pole 40 Amp 120V Coil Definite Purpose Contactor
Feature
- 200K cycles UL testing approval for Dp contactor
- Contactor meet specifications for devices up to 600 VAC
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard
- Contactor Coils have class b insulation
- Replacement parts number: 45GG20AF,HCCY2XT04GG, C240B, DP401202.
Description
Replacement for: Square D, Siemens/Furnas, Fasco, GE, Cutler Hammer, Allen Bradley, Arrow Hart, Joselyn Clark,Packard,Hartland Controls(HC),Supco,Rheem,Goodman.
Replacement parts number:
45GG20AF,HCCY2XT04GG, C240B, DP401202.
9. Packard C330B 3 Pole 30 Amp Contactor 120 Volt Coil Contactor
10. Electrodepot 30 Amp 6 Pole (3 Pole x 2) Normally Open | Auxiliary 1NO/1NC | 110/120VAC Coil | Motor Load 32A, Lighting Load 50A | Contactors Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
Feature
- BUNDLE CONTENT: 5 ITEMS – Two (2) 30A 3 Pole Normally Open (NO) Contactors with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2″) for immediate home or industrial installation
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters
- and AC-3 for air conditioners, compressors or fans
- COIL VOLTAGE AND LOAD – Contactor IEC 660V. Coil Voltage 110/120VAC, 50/60 Hz
- Coil load Inrush 70VA, Sealed 7.5VA. Inductive/Motor Load: 32Amp, Resistive/Incandescent Load: 50Amp. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp and 50 Amp loads. Power Lug Terminal Capacity AWG # 4
- OTHER CONTACTOR DETAILS – Contactor type NO with 3 poles and 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. Dimensions (approx.): 89 x 56 x 89 mm / 3.5” x 2.2” x 3.5” (Length x Width x Height)
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 150mm (6″) and thickness 5mm (0.2”)
Description
ABOUT CONTACTOR
30 Amp 6 Pole Normally Open Contactors (3 Pole x 2) for home or industrial uses.
With applications in lighting, motor and switching.
Technical Specifications:
– Contactor 660V
– Contactor Type IEC
– Inductive Load: 32A
– Resistive Load: 50A
– Number of Poles 3 x 2
– Coil Volts: 120VAC
– Hz 50/60
– Action: Non-reversing
– Enclosure Type Open
– Auxiliary Contact Form 1NC/1NO
– Coil inrush 70VA, Sealed 7.5VA
– 2 HP @ 1 Phase – 120V
– 5 HP @ 1 Phase – 230V
– 10 HP @ 3 Phase – 208V
– 10 HP @ 3 Phase – 230V
– 20 HP @ 3 Phase – 480V
– 30 HP @ 3 Phase – 575V
– Width: 2.22″ (56.4 mm)
– Height: 3.50″ (88.9 mm)
– Depth: 3.50″ (88.9 mm)
– Standards CE
– Base or DIN 35mm mount
Wiring:
Solid Conductor: 25 mm2 Max torque 0.6 Nm
Stranding Conductor: 16 mm2, Max torque 0.6 Nm
Compliance:
CSA C22.2 No. 14, EN 60947-4-1, EN 60947-5-1, IEC 947-2, IEC 60947-4-1, IEC 60947-5-1, UL 508
ABOUT DIN RAIL
DIN Rails are the standard mounting support for any electromechanical component, device or equipment
designed using the DIN specifications adopted by European (EN) and international (IEC) standards.
The rail features slots throughout its length making it easy to attach to a panel, wall or equipment.
For support of mini circuit breakers, contactors, auxiliary relays, terminal blocks, low voltage apparatuses, etc.
– Width: 35mm (1.375”)
– Length 150mm (6”)
– Thickness 5mm (0.2”)
ABOUT SCREWS
Drive stainless steel truss head screws (#10, 1/2″”) for immediate installation.
Conclusion
By our suggestions above, we hope that you can found Ge Cr353ady34h Contacter for you.Please don’t forget to share your experience by comment in this post. Thank you!